top of page

GUNTNER ADIABATIC HIGH DENSITY

Adiabatic Operating Principle
Güntner’s ADC HD can be used either wet or dry. Both modes offer excellent dry cooler performance with a small footprint and low operating costs. The cooling limit, i.e. the theoretically best possible return temperature for the ADC HD is tied to the wet bulb temperature of the ambient air at the heat exchanger. Our experts will configure the ADC HD specifically for your application and optimize it for use in your system. This is the only way of optimally dimensioning the dry coolers and minimising the cost of operating the entire system. 

Güntner_logo_rgb-01.png
Pages from RPG - Guntner ADC HD Info Brochure EN-3.png

Dry or wet – performance as required

Adiabatic operating principle
Güntner’s ADC HD can be used either wet or dry. Both modes offer excellent dry cooler performance with a small footprint and low operating costs. The cooling limit, i.e. the theoretically best possible return temperature for the ADC HD is tied to the wet bulb temperature of the ambient air at the heat exchanger.

Our experts will configure the ADC HD specifically for your application and optimize it for use in your system. This is the only way of optimally dimensioning the dry coolers and minimising the cost of operating the entire system. 

The smart hydroBLU™ control unit continuously  records the amount of water applied, the speed of the fans and the state of the ambient air. This reduces your operating costs without any loss of performance, thus saving you money. The necessary information for this such as the fan speed is read out from Güntner  Motor Management GMM via the bus communication. This speed information can alternatively be transmitted  using a 0 – 10 volt signal.

Efficiency mode
The hydroBLU™ is also capable of checking the operating costs during oper-ation. This provides the basis for an integrated cost management function, which continually decides whether applying water or changing the speed represents the more cost-saving and therefore more efficient mode of oper-ation. To this end, the water quantity is constantly recorded in this system.

Guntner ADC HD In Detail

​One controller – everything under control

  • Intelligent hydroBLU™ controller regulates fan speed and humidification

  • Large display for operation and visualization

  •  Very low energy consumption thanks to the use of highly efficient EC fan motors

  • Very low water consumption thanks to a high dry/wet switch point

  • hydroBLU™ water metering control measures humidity and fan speed to use only as much water as needed to meet process temperature

​​Perfect adjustment, easy bringing-in procedure

  • Ideal dimensions: units ship in two pieces and stacked on site

  • Torsion-resistant construction

  • Factory-fitted transport lugs

  • Simple crane transport without lifting beam

 Numerous possible combinations

  • Various combinations of materials

  • Configurable tube materials and geometries

  • Various tube circuitry options

  • Various fin spacings possible

High Density – compact and powerful

  • Maximum thermal performance with a small footprint

  • Very large heat exchanger surface over the entire height of the unit

  • Use of high-performance super low noise fans

​Easy inspections, cleaning and maintenance

  • Inspection doors ensure easy accessibility

  • Easy to clean thanks to robust materials and clever design

  • Spare parts available quickly anywhere in the world

  • Optional OSHA platform available for easy fan access

Highly efficient humidification system

  • Robust and cost efficient humidification pad

  • Humidification pad is close to coil along full surface area providing maximum and uniform cooling

  • No spraying on coil

  • Unlimited wetting duration

  • No water recirculation

  • No water treatment required

​Adiabatic pre-cooling boosts performance 

  •  Fluid cooling to below the ambient temperature is possible

  • For high outdoor temperatures or heavy system loads

  • Without direct wetting of the heat exchangers

  • Energy can be dissipated by convection

H​ygienic operation

  • Automatic draining of the adiabatic system

  • Dry heat exchanger

  • No aerosol emissions

  • Plume-free

  • Filtering effect of the pads protects heat exchangers

HD Cover Snip.PNG
Pages from RPG - Guntner ADC HD Info Brochure EN-4.png

Safe and hygienic operation

The clever design of the ADC High Density takes into account the recognized technical rules when it comes to the hygienic operation of evaporative cooling systems. The pre-cooling unit with humidification fluid is completely separate from the heat exchanger. 
The humidification controller supplies the easily replaceable humidification pads only with the amount of water needed depending on the particular situation. This minimizes water consumption and prevents standing water. In the event of inactivity, the pre-cooling unit is automatically drained. The factory-fitted feed water line can also be drained or ventilated via the unit.
Güntner offers its customers added value on three levels: expert advice over the entire life cycle of units, safety thanks to carefully constructed units equipped with suitable control systems and certified employees.

Inspection + Maintenance

The ADC HD is easy to work on. 
Not only are all spare parts available anywhere in the world, our ser-vice staff can assist you if you request this. The service includes all work which is necessary over the entire life cycle – from commission-ing to disassembly.

HD Cover Snip.PNG